Cleaning, disinfecting, sterilizing, and maintaining medical and dental devices should follow the manufacturer’s Instructions for Use (IFU), not habit or assumption. IFUs are based on testing and validation that show a device can be safely reprocessed and reused without compromising its function or patient safety. When an IFU isn’t followed, the validated process has been changed.
Why IFUs Matter
Depending on the device or product, an IFU may specify:
- Cleaning procedures and approved cleaning agents
- Disinfectant dilution and application instructions
- Required wet contact time
- Lubrication requirements
- Sterilization temperature, pressure, and cycle parameters
- Compatible chemicals and products
- Frequency of cleaning or disinfection
- Storage requirements
- Maximum number of reprocessing cycles
Changing any one of these can affect the effectiveness of the entire process. For example, EPA-registered disinfectants must be used according to their label. If a surface dries or is wiped off before the required contact time, the disinfectant may not work as intended. CDC guidance also notes that using a product inconsistently with its labeling places responsibility for the consequences on the user.
Reusable Devices Require Validated Reprocessing
Reusable devices, including dental handpieces, must be processed according to the manufacturer’s instructions, which may cover cleaning, lubrication, packaging, disinfection, and heat sterilization. CDC recommends that dental handpieces and other removable intraoral instruments be cleaned and heat sterilized between patients according to validated manufacturer instructions. Staff should not create their own methods because they seem faster or more familiar.
IFUs Should Be Easy to Find
Facilities should keep current IFUs organized and accessible, whether as electronic files, manufacturer websites, printed manuals, or an IFU management system. CDC recommends keeping reprocessing instructions in or near the reprocessing area. The Joint Commission expects manufacturer instructions to be built into policies, procedures, education, and competency, and QUAD A requires IFUs to be organized and readily available to staff and biomedical personnel. A well-organized system also helps during inspections and accreditation reviews.
Single-Use Means Single-Use
Single-use items are for one patient during one procedure and should never be reprocessed. Per CDC dental guidance, a device without reprocessing instructions should be treated as single-use. If a device appears reusable but no instructions can be found, contact the manufacturer before cleaning, disinfecting, or sterilizing it.
Stop the “We’ve Always Done It This Way” Cycle
Incorrect practices often persist through verbal training passed from one employee to the next. Familiar is not the same as correct. Processing should be based on current IFUs, evidence-based guidance, and facility policy. Staff should know where IFUs are kept and how to interpret them, and training should explain why details like dilution, contact time, temperature, cycle selection, lubrication, and compatibility matter. Review IFUs periodically, since manufacturers update them.
Make IFUs Part of Everyday Practice
Review the IFU before any new equipment, instrument, disinfectant, or sterilization product is put into service, and check that facility procedures still match current instructions. FDA guides manufacturers in developing validated reprocessing instructions, and ANSI/AAMI standards emphasize following them.
Take Action
Review your facility’s IFU process:
- Are your IFUs current?
- Can staff access them quickly?
- Do your written procedures match manufacturer instructions?
If not, fix it now. Find the IFU and follow the validated process.